HighStakesthrill

Why the calibration of (force) measuring instruments is important

Everyone involved with measurement technology knows the somewhat flippant ? but very catchy ? statement: ?If you measure a whole lot, you measure nothing!? What is meant by this is: It is possible to measure a lot. But the values are only useful if you can validate them. In everyday activity, for example, one may be surprised when the scales in the home show a large deviation from those at the physician?s or the bicycle speedometer deviates many hundreds of metres from the GPS instrument. The saying also often alludes to our tendency to generate more and more data inside our modern world, without thinking about its evaluation. As a way to obtain valid data with which to keep working, it really is worthwhile for industrial measuring instruments to be calibrated regularly.
For the individual, the best accuracy will not be important. In industrial applications, however, it really is precisely this that can make the crucial difference between rejects and the highest quality ? hence Lawsuit of the measuring instruments. It serves to match the measuring device with the national standard ? in a nutshell: to check if the values are correct.
Traceability to the national standard
The keyword here’s thus the traceability to the national standard. Realizing that the respective measuring instrument measures the proper value could be of great importance for most applications. For example, ISO 9000 requires that the deviations of the test equipment used should be monitored. With an up-to-date calibration, passing the audit is no problem. This avoids the repetition of the audit, production downtime or perhaps a recall ? and therefore reduces stress, time and costs. The expenditure on the calibration has thus quickly covered itself. Everyone is happy.
Besides meeting the audit requirements, traceability can also be required for quality assurance, optimising resource utilisation and reducing energy consumption. Finally, probably the most convincing reason to have one?s own measuring devices checked relative to the current standard is the feeling of security: The measuring instruments will continue steadily to provide the correct values!
Certification relative to the German accreditation body
The illustration shows how the four calibration sequences relative to DKD-R 3-3 differ.
The highest standard for this may be the calibration certificate of the German accreditation body (Deutsche Akkreditierungsstelle ? DAkkS). WIKA has offered certification for pressure, temperature and electrical measurands (DC current, DC voltage and DC resistance) for quite a while. Because the beginning of 2022, tecsis has been accredited in accordance with DIN EN ISO / IEC 17025 for the measurand force.
Just what a DAkkS-certified calibration of force measuring instruments means is shown by the exemplory case of high-end force transducers, which are used in calibration machines. Within their case, the test sequence follows the EN ISO 376 standard. At the very least eight measuring stages are approached, with a total of five preloads, two upward series and two up-down series. In addition, the force transducers are each rotated by 120�, which results in three installation positions. With 65 measured values (eight stages), your time and effort is correspondingly high. The price for such a calibration goes hand in hand with this.
In the case of industrial devices, the question arises as to whether this type of procedure is worthwhile. Alternatively, the DKD-R 3-3 directive could be applied. It describes four test sequences which can be selected in line with the requirements. WIKA and tecsis likewise have DAkkS certification because of this.
An additional option for regular calibration may be the non-standardised 3.1 inspection certificate.
Practical examples
An illustrative example of the usefulness of regular calibration may be the checking of hydraulic compression force transducers. These instruments gauge the clamping forces of industrial machines such as for example punches, pneumatic presses, sealing presses, spindle presses, tablet presses and toggle lever presses. Here, calibration provides a contribution to ensuring safe working conditions.
Another example may be the instrumentation for checking the contact forces of welding tongs. Ideally, these are monitored continuously by built-in tension/compression force transducers, but they may also be checked at set intervals using a test set for measuring electrode forces (model FSK01). This ensures the quality of the welding points and reduces wear on the electrodes.
For the tension/compression force transducers mentioned, calibration can be worthwhile, should they be utilized for monitoring very precise production steps. When pressing in cellular phone displays, for example, both the measuring instruments and their calibration can easily pay back: If one in such a process isn’t noticed immediately (for example, only if the travel is controlled), several thousand euros in material value can be destroyed within minutes.
Adjustment before calibration can be handy
According to the instrument, application and regulation, it might be worthwhile with an adjustment carried out before calibration. In this way, the user ensures that their measuring instrument achieves the corresponding accuracy during calibration. For the calibration itself, the user has the option of choosing the sort and procedure, both for our own and for third-party products.
Note
On the WIKA website you can find further information on the average person calibration services as well as on WIKA force measuring instruments (offers are also available in the web shop). Should you have any questions, your contact will gladly help you.
Also read our post
Calibration or adjustment ? Where?s the difference?

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top